Quick answer#
Estimate a one-zone cooling load, compare nominal mini split sizes and check your own design cooling and heating loads. The result updates as you edit inputs. Choose a contextual example to populate visible fields, then replace the example with your actual measurements or professional design values.
Formula and calculation method#
The illustrative load is conditioned zone area × the editable load rate. A supplied cooling design load replaces that illustration. Nominal catalog sizes are a comparison, not a product recommendation.
US customary and metric inputs use one internal SI calculation path. Each displayed quantity is converted after the calculation. Presets only fill editable inputs; no undocumented material, performance or cost adjustment is made.
Worked example#
A 300 ft² zone at an illustrative 20 BTU/h per ft² yields 6,000 BTU/h. Enter an actual design load when available; check manufacturer capacity at the design conditions.
Open the calculator above, select the matching example and review every dimension or rate before using the result. The PDF report includes your entered values and documented limits.
Selecting inputs and project assumptions#
The input units change together when you switch measurement systems. A project preset is a starting point, not an instruction to buy a product or select a construction assembly. Local materials, engineering plans and supplier quotations have priority over illustrative defaults.
Cost inputs, if available, use only the numbers you provide. The currency selector changes the label and does not fetch exchange rates or regional prices. The calculation report identifies its formula, input assumptions and sources.
Assumptions and limitations#
An area factor does not account for climate, insulation, windows, leakage, internal gains, humidity or equipment modulation. This is not a Manual J load calculation or Manual S selection, and a nominal size is not delivered capacity.
Use this result for preliminary planning. Measure the actual project, obtain the required design or specification, confirm available product sizes and tolerances, and verify purchases with the supplier or contractor. A calculation cannot inspect site conditions or guarantee a finished quantity.
Sources and methodology#
- ACCA Manual J — reference for the relevant method, standards or units; no source certifies these illustrative presets.
- ACCA Manual S — reference for the relevant method, standards or units; no source certifies these illustrative presets.
- U.S. DOE on HVAC sizing — reference for the relevant method, standards or units; no source certifies these illustrative presets.
Sources support the stated method and context. Any editable preset or illustrated cost is an Efficienco example, not a quotation, standard-prescribed value or endorsement by the linked organization.